{"title":"Refrigerated Air Dryers","description":"","products":[{"product_id":"california-air-tools-rd-91502-high-efficiency-non-recycling-98-refrigerated-air-dryer","title":"California Air Tools RD-91502 52.97 CFM Refrigerated Air Dryer 115V","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003cp\u003eCalifornia Air Tools RD-91502 is a refrigerated air dryer designed to reduce moisture content in compressed air systems for general-purpose industrial use. The unit is configured to operate downstream of an air compressor to improve air quality before distribution to tools or equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe system uses a refrigeration cycle with R134A refrigerant to cool incoming compressed air, allowing moisture to condense and separate from the airflow. The resulting pressure dew point range of 2°C to 10°C (35.6°F to 50°F) supports applications where moderate dryness is required.\u003c\/p\u003e\n\n\u003cp\u003eWith a rated flow capacity of 52.97 CFM and a working pressure range of 29 to 232 PSI, the dryer is compatible with a range of compressed air systems. The unit operates within ambient temperature conditions from -5°C to +60°C (23°F to 140°F).\u003c\/p\u003e\n\n\u003cp\u003eThe dryer is equipped with 3\/4\" NPT inlet and outlet ports for integration into standard air lines. Electrical operation is supplied by a 115V, single-phase connection with a power requirement of 0.5 kW.\u003c\/p\u003e\n\n\u003cp\u003eFor system integration, the dryer is typically installed after the compressor and before final point-of-use equipment. Pre-filtration may be required to remove particulates prior to entering the dryer, depending on compressor output conditions.\u003c\/p\u003e\n\n\u003ch2\u003eStandard Equipment\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerated air dryer unit\u003c\/li\u003e\n\u003cli\u003eIntegrated refrigeration system (R134A)\u003c\/li\u003e\n\u003cli\u003e3\/4\" NPT inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eInternal moisture separation system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Data + Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.97 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2°C to 10°C (35.6°F to 50°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29–232 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5°C to +60°C (23°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR134A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 60Hz \/ Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 8573 Class 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.18\" L × 16.92\" W × 25.98\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse Case\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture Removal \/ Compressed Air Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Year Limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"California Air Tools","offers":[{"title":"Default Title","offer_id":47659403706613,"sku":"RD-91502","price":1625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/9021\/9509\/files\/RD_95102_Front-Angle-Tight-scaled.jpg?v=1772911945"},{"product_id":"california-air-tools-rd-91503-high-efficiency-non-recycling-98-refrigerated-air-dryer","title":"California Air Tools RD-91503 52 CFM Refrigerated Air Dryer 220V","description":"\u003cdiv class=\"product-description\"\u003e\n\n\u003cp\u003eCalifornia Air Tools RD-91503 is a refrigerated air dryer designed for integration into compressed air systems to reduce moisture content prior to end use. The unit is typically installed downstream of an air compressor to improve air quality and system consistency.\u003c\/p\u003e\n\n\u003cp\u003eThe system utilizes a refrigeration cycle with R134A refrigerant to lower the temperature of compressed air, allowing moisture to condense and be separated from the airflow. This process supports a pressure dew point range of 2°C to 10°C (35.6°F to 50°F), suitable for general-purpose drying applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit is rated for approximately 52 CFM and operates within a working pressure range of 29 to 145 PSI. It is designed for use in environments where inlet air temperatures may be elevated, with a maximum inlet temperature rating of 176°F.\u003c\/p\u003e\n\n\u003cp\u003eElectrical operation is supplied by a 220V, single-phase power source with a power consumption of 0.5 kW. The dryer connects to standard air systems using 3\/4\" NPT inlet and outlet ports.\u003c\/p\u003e\n\n\u003cp\u003eFor system setup, the dryer is installed between the compressor and the point of use. Pre-filtration may be required to remove particulates before entering the dryer. Additional air storage can be used upstream to help stabilize pressure during operation.\u003c\/p\u003e\n\n\u003ch2\u003eStandard Equipment\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerated air dryer unit\u003c\/li\u003e\n\u003cli\u003eIntegrated refrigeration system (R134A)\u003c\/li\u003e\n\u003cli\u003e3\/4\" NPT inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003eInternal moisture separation system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Data + Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2°C to 10°C (35.6°F to 50°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29–145 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Inlet Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR134A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V \/ 60Hz \/ Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.18\" L × 16.92\" W × 25.98\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse Case\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Moisture Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"California Air Tools","offers":[{"title":"Default Title","offer_id":47659409015029,"sku":"RD-91503","price":852.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/9021\/9509\/files\/RD-91503_Angle.jpg?v=1772911957"}],"url":"https:\/\/sawdustsupplies.com\/collections\/refrigerated-air-dryers.oembed","provider":"Sawdust Supplies","version":"1.0","type":"link"}